Eight IO Installation

You will connect 115VAC to the Black and White input leads on the Altronix transformer. For connecting to a 110v outlet you will need a:

Grounded 3-Wire Line Cord 

Or you can wire it directly to the 110v power source.
*Note-Always check for proper voltage before connecting any hardware*
The Yellow and Brown leads will connect to AC / AC on the SMP10 board *Note cut and tie off the black wire on the output side of Altronix transformer*:
SMP10


The DIP switch needs to be in the ON position. Connect an 18/2 wire from the + and - DC terminals to the EIO