We have resources available to help you manage your Storable Settings if you’re impacted by the Central Texas floods or Tropical Storm Chantal. If you need additional help, please call us at 888.403.0665. Stay safe!

Eight IO Installation

You will connect 115VAC to the Black and White input leads on the Altronix transformer. For connecting to a 110v outlet you will need a:

Grounded 3-Wire Line Cord 

Or you can wire it directly to the 110v power source.
*Note-Always check for proper voltage before connecting any hardware*
The Yellow and Brown leads will connect to AC / AC on the SMP10 board *Note cut and tie off the black wire on the output side of Altronix transformer*:
SMP10


The DIP switch needs to be in the ON position. Connect an 18/2 wire from the + and - DC terminals to the EIO
Still have questions?
Don't be afraid to ask us. We're here to help you.