Follow the steps below to integrate your Digi Gate software with Easy Storage Solutions.
1. Go into your Easy Storage solutions website and install the Gate Sync Program.
2. When setting up your Gate Sync Program, make sure to put your facility code in. The facility code can be found at the bottom of your "Gate" page in the ESS software, SETUP>Gate. The Post Download Action setting located on the ESS Gate Sync Program you need browse for the digi folder and then select the, digisend.exe icon and hit save. This should put the digisend.exe verbiage into the post download action setting.
3. Setup the Digi software to read the gate file that the Easy Storage Software creates:
a. Open up the DigiGate Program.
b. Select setup.
c. Select SysCon Setup Tab.
d. Select Accounting Button.
e. Select SAGE from the drop down list.
f. Select "Link File" tab (next to Accounting Company tab)
g. Change "file name" to toread.fil
h. Select Ok and the YES to save changes.
i. Exit and restart the DigiGate program for the changes to take effect. Digigate should remain open for the communication to work properly.
j. Once the new file has been downloaded into this "C:digi" folder DigiGate should read the file and update the gate system accordingly. DigiGate should change LINK.fil file to a LINK.old file once it has been updated.
MULTIPLE GATE CODES PER UNIT:
We cannot have 2 codes assigned to one unit, to allow 2 or more codes dummy units must be created in Easy Storage Solutions software and assigned the extra codes. When renting you can assign a 100% discount on the dummy account to ensure this does not cause billing issues.
OTHER NOTES and TROUBLESHOOTING:
1. Your computer may need to be on Microsoft .net 4.5 framework if you are having problems with your ESS gate sync software
2. Communication from other outside software programs(previous management systems) need to be halted in order for the ESS gate sync post download action to work.
Just had an issue where everything was working fine with ESS gate sync was downloading link.fil properly, however the post download action wasn't clicking the "digisend.exe" I could do it manually and click the digisend.exe and it would update digigate just fine.
3. If you are having a problem installing the gate sync program, make sure you are logged in to your computer using an admin account that is secured with a password.
TABLE IS FULL ERROR
Usually if you get a "Table is Full" error in Digiwin, the transaction log is either corrupt or it is too large to process.
2. Open Dataview.exe (the login is digi, and password 1989).
3 Select the Open Database button and navigate to the Transaction.db file and select it and select open.
4. Select the Delete All Button and then select the Close Database button.